When an interface engine goes down, nobody needs to be told. Phones ring, clinicians complain, and the downtime procedures come out of the drawer. The harder problem is the automation that keeps running while quietly doing the wrong thing, or nothing at all. That was the focus of a November 13 panel at the CHIME26 Fall Forum titled "Where Control Breaks: What's Actually Happening Inside Our Systems," as reported by Anthony Guerra at healthsystemCIO.

The panel's message was blunt. AI tools, bots, automations, and applications built by staff (and increasingly used by patients) are spreading faster than health systems can review them. Moderator Tressa Springmann framed the problem the same way: innovation is outpacing governance. The useful part for the rest of us is that the panelists described specific, mostly unglamorous controls that work, and most of them do not require a large team or a new platform purchase.

At a glance

The problem: Automations, AI tools, and staff-built apps can fail silently. Nothing goes down, but work stops moving, and nobody notices until harm occurs.

What to do, in order:

  1. Inventory the bots, automations, AI tools, and outside connections you know about, and assign each an owner.
  2. Alert on abnormal patterns (queue depth, daily volumes, missing transactions), not just on outages.
  3. Route outside connections through one point you can shut off.
  4. Require someone other than the builder to review and promote anything into production.
  5. Put privileged production access behind credential checkout.
  6. Document that clinical and operational leaders make downtime calls, and that IT supplies status and update timing.

Who was on the panel

Springmann, SVP and Chief Information and Digital Officer at LifeBridge Health, moderated. The panelists were Stuart James, VP, Chief Operations Officer and Deputy CIO at CHRISTUS Health; Rachini Moosavi, Chief Analytics Officer at UNC Health; and Bonnie Boles, MD, SVP and CMIO at Tanner Health, which healthsystemCIO describes as a five-hospital system in west Georgia and east Alabama. The Fall Forum ran November 11 through 14 at the Gaylord Rockies Resort and Convention Center in Aurora, Colorado, in the Denver area, according to event listings.

That mix matters. CHRISTUS and UNC Health are large systems, but Tanner is a regional system, and several of the examples came from ordinary clinical departments rather than from enterprise IT.

The failure nobody pages you about

James framed the core issue in one line: "In many cases, downtime is the easy part, because you know it's broken." He described a scenario, offered to illustrate the risk rather than as a documented incident, in which a referral bot stops working and referrals sit stuck for six to eight months, and "a few of those patients have died." Nothing crashed. No error screen appeared. The work simply stopped moving.

His answer was to tune monitoring to what normal looks like, not just to whether a service is up. Two of his examples are worth borrowing directly. If a queue normally holds about 1,500 items and suddenly holds 12,000, something is wrong even if every server is green. If a clinic normally gets three or four cardiology referrals on a Monday and gets none, something is wrong even though zero is not an error.

He also gave an example of this kind of monitoring paying off. During the 2024 Change Healthcare attack, James said, CHRISTUS's monitoring sent an automated overnight page reporting that the organization was no longer talking to Change. The team shut off access until it knew more.

For most organizations, the gap here is not tooling. Interface engines, EHR work queues, and most monitoring platforms can already count things and alert when counts fall outside a range. The gap is that nobody has written down what normal looks like for each feed, queue, or bot, so nobody has set the thresholds.

Controls are getting diluted

Moosavi said the control piece "is getting very diluted," and offered an example that should make any security officer wince: someone at UNC Health had set up a model context protocol (MCP) server on a personal computer to run large jobs for work. MCP is a way of connecting AI models to tools and data. Running one on a personal machine means work data and work processing are happening on a device the organization does not manage.

Boles described finding a 79-member group text among cardiovascular OR staff at Tanner. The group said it kept patient information out of the thread, and Tanner is moving the group to a secure messaging platform. The takeaway is not that staff were malicious. They built the communication channel they needed because the sanctioned one did not meet the need, and a thread that size makes it hard to keep protected health information out over time. Boles also noted that when clinicians bring in ECG-reading apps, those go to Tanner's AI governance committee for review rather than being blocked outright or quietly tolerated.

Patients are part of this too. Moosavi described a message on a thread asking how UNC Health handles patients who use AI agents to call its call center and book appointments. The source presents this as an emerging question rather than a documented incident, but it is a fair one for any organization with a scheduling line: how does your call center verify who, or what, it is talking to? Moosavi cited a line she heard at Epic's user group meeting, that providers move at the "speed of trust" while patients move at the "speed of desperation," and she added that convenience drives patients as well.

What CHRISTUS does about it

The most transferable part of the session was James's description of how CHRISTUS keeps control without banning experimentation, per healthsystemCIO.

One chokepoint for outside connections. CHRISTUS routes every outside connection through a central integration platform. That turned 15 or 16 separate Change Healthcare links into one connection it could shut off. When a trading partner is compromised, the difference between one switch and sixteen is measured in hours.

Credential checkout for production. Under its zero-trust approach, even analysts must check out privileged credentials to touch production. Standing admin access is where silent, untracked changes come from.

A safe place to build, and a gate to production. Builders get a lower environment. Promotion to production requires change control by people who did not build the tool. Reports go through the same review.

That last point deserves attention. Many organizations have change control for servers and interfaces but not for reports, Power Automate flows, macros, or AI prompts that staff build themselves. Those are exactly the items most likely to break silently when an upstream field changes.

Who decides when to go to downtime

The panel was clear that IT should not be the one deciding whether clinical operations shift to downtime procedures. At Tanner, downtime authority starts with the chief nursing executive, CMO, and chief quality officer, with the CIO closely involved, and Tanner also formed a committee it calls READI. James described IT's role as telling operators what it knows, what it does not know, and when the next update will come. Operators decide what is safe.

James also made the point that incident management is an operational function, and that FEMA offers free incident management training. For a small hospital where the CNO and administrator have never sat through incident command training, that is a no-cost starting point. If your organization has never tested who actually makes the call, a widespread cloud service outage makes a realistic tabletop scenario.

The numbers behind the concern

The panel landed the same day CHIME released its 2026 Digital Health Most Wired findings. According to CHIME's November 13 release, 93.2% of participating organizations use AI in clinical or operational processes, and fully adopted generative AI rose from 31.0% to 54.8% in one year. Only 16.4% of AI users have fully documented processes for monitoring models after deployment, a figure MarketScale also reported. Note that the 16.4% is a share of organizations using AI, not of all participants. We covered the full report in CHIME's 2026 Most Wired Report: AI Use Hits 93% While Oversight Trails Behind.

Put the panel and the survey together and the picture is consistent: adoption is broad, and post-deployment monitoring, the exact control that catches silent failures, is the weakest link.

Scaling this down to a small organization

None of the panelists' organizations is small, so it is fair to ask how this translates to a 25-bed Critical Access Hospital with a two-person IT team or an outsourced IT provider. The panel did not address that directly, so what follows is our editorial view of how the same ideas apply with limited resources.

Start with a list, not a platform. A spreadsheet with every bot, scheduled task, interface, report subscription, and AI tool you know about, plus its owner, its data source, and what normal output looks like, is a real control. Ask department managers what their staff built or signed up for. You will find things.

Use what you already own as the chokepoint. If your interfaces run through an interface engine or your EHR vendor's integration layer, that is your chokepoint. Document how to disable each outside connection and who is authorized to do it. If connections bypass it, note them as gaps.

Count things. Pick the five feeds or queues that would hurt most if they stopped silently, such as lab results, referrals, e-prescribing, claims, and patient portal messages. Set a daily low-volume alert on each. Even a scheduled report that a person reviews every morning beats nothing.

Find a non-builder reviewer. A solo IT person cannot be both builder and independent reviewer. The reviewer does not need to be technical for every item. A clinical informatics nurse, a department manager, or your outside IT provider can confirm that a report or automation produces the right output before it goes live. The point is that the person who built it is not the only person who looked at it.

Write down who calls downtime. One page, signed by the administrator and CNO, naming who decides and what IT provides is enough to start.

Where HIPAA fits

The panel did not discuss HIPAA, and the mapping below is ours. But several Security Rule provisions in 45 CFR Part 164 bear directly on unmonitored automations and staff-built tools that touch electronic protected health information (ePHI).

PracticeRelated provisionWhat the regulation says
Inventory and assess staff-built tools and AI164.308(a)(1)(ii)(A) and (B)Risk analysis (Required) and risk management (Required) covering risks to the confidentiality, integrity, and availability of ePHI
Pattern monitoring and log review164.308(a)(1)(ii)(D) and 164.312(b)Information system activity review (Required); the audit controls standard requires mechanisms that record and examine activity in systems containing or using ePHI
Credential checkout and named accounts for bots164.312(a)(1) and (a)(2)(i)The access control standard allows access only to persons or software programs granted access rights; unique user identification (Required)
Re-review when tools or workflows change164.308(a)(8)The evaluation standard calls for periodic evaluation, including in response to environmental or operational changes affecting ePHI security
Downtime planning164.308(a)(7)Contingency plan standard with Required specifications (data backup, disaster recovery, emergency mode operation) and Addressable ones (testing and revision, applications and data criticality analysis)

Two details are worth calling out. First, the access control standard at 164.312(a)(1) explicitly covers "software programs," not just people. A bot running under a shared or personal account is an access control problem, not just a governance problem. Second, the contingency plan standard at 164.308(a)(7) is not entirely Required. Testing and revision procedures and applications and data criticality analysis are Addressable, which does not mean optional: the organization must either implement them or document why an equivalent alternative is reasonable and appropriate. A criticality analysis is also a natural place to rank which silent failures would hurt most. If your contingency plan needs work, our disaster recovery planning guide for rural health care covers the basics.

HIPAA does not say who must make downtime decisions. The panel's point about clinical and operational leaders owning that call is an operational practice, not a regulatory requirement.

What is still unanswered

The session left real questions open. The panelists shared anecdotes and practices, not measured results, so we do not know how much pattern monitoring or non-builder promotion gates reduce silent failures in practice, or what thresholds the panelists' organizations use to define abnormal. Liability for appointments booked or influenced by a patient's AI agent is unsettled. And the panel did not address how these practices scale to the smallest organizations, which is where a single unmonitored bot can represent a large share of a department's workflow.

What is clear is that the old rules still apply. Know what is running, know what normal looks like, keep builders from promoting their own work, and keep the people responsible for patient safety in charge of the decisions that affect it.

This article is for informational purposes only and does not constitute legal or compliance advice. Covered entities and business associates should consult qualified legal counsel or compliance professionals before making decisions pertaining to HIPAA or IT infrastructure.

Sources

About the Author

Health Tech Authority Editorial Team

Health Tech Authority is a publication covering the technology side of health care organizations. We exist for the people in the mix - the systems administrators keeping servers online at 2 AM, the network engineers segmenting clinical VLANs on a shoestring budget, the security officers trying to hold the HIPAA line with half the resources a comparably sized non-health care organization would have, and the IT managers and administrators making technology decisions that directly affect patient care.

Content published under this account represents collaborative editorial work produced by the Health Tech Authority team. That includes original reporting, technical analysis, regulatory coverage, and practitioner-focused guidance across our core coverage areas: infrastructure and systems administration, networking, security and compliance, cloud and Microsoft 365 administration, clinical systems and health data, and the broader technology landscape serving health care organizations.

We cover what health care IT professionals actually need to know, written in a way that respects both their time and their intelligence. No fluff, no vendor press release rewrites, no thought leadership buzzword soup - just straightforward coverage of the systems, tools, and decisions that keep health care organizations running.

If you have a topic suggestion, a correction, or want to contribute, reach out through the Contact page.