Skip to main content

Netgate Ships 19 pfSense Security Advisories: Upgrade to CE 2.9.2 or Plus 26.07.2 Now

A rack-mounted firewall appliance with lit network ports and patch cables, with glowing light streams representing secure VPN tunnels extending from it.

Netgate published nineteen security advisories for pfSense on November 17, 2026, numbered pfSense-SA-26_23 through pfSense-SA-26_41. France's national CERT relayed them the next day in CERTFR-2026-AVI-1557, which lists the affected products as pfSense Community Edition (CE) before 2.9.1 and pfSense Plus before 26.07.1. CERT-FR lists the risks as remote arbitrary code execution, privilege escalation, remote denial of service, security policy bypass, cross-site scripting, and loss of data confidentiality and integrity.

Netgate shipped fixes the same day in CE 2.9.1 and Plus 26.07.1. Two days later, on November 19, it followed with CE 2.9.2 and Plus 26.07.2, which add more FreeBSD, PHP, and nginx updates. Several of the documented flaws require an authenticated session, which takes some of the edge off. Even so, the firewall is the device that decides who reaches your EHR, your remote providers, and your cloud connections. If pfSense sits at the edge of your clinic, hospital, or multi-site practice, finish this patch cycle this week, not next quarter.

At a glance

Affected: pfSense CE before 2.9.1 and pfSense Plus before 26.07.1. Seventeen advisories cover the web GUI and two cover OpenVPN.

Fixed: CE 2.9.1 and Plus 26.07.1 (November 17). CE 2.9.2 and Plus 26.07.2 (November 19) include all of those fixes plus more.

What to do, in order:

  1. Confirm the web GUI is reachable only from a trusted management network or VPN.
  2. Take a configuration backup, then upgrade directly to CE 2.9.2 or Plus 26.07.2.
  3. If you cannot upgrade yet, apply the Recommended System Patches (Plus 26.07 and 26.03.1, CE 2.9.0 and 2.8.1).
  4. Review administrator and IPsec Mobile privileges, OpenVPN configurations, and recent GUI logins.
  5. Put an IKEv1-to-IKEv2 migration on the calendar.

What Netgate Fixed

Of the nineteen advisories, CERT-FR's listing shows SA-26_35 and SA-26_36 are filed against the OpenVPN module, and the remaining seventeen are filed against the web GUI. The nineteen advisories map to seventeen CVE IDs: CVE-2026-111214 through CVE-2026-111220, CVE-2026-111222 through CVE-2026-111228, CVE-2026-111230, CVE-2026-111232, and CVE-2026-111233. If you track vulnerabilities in a spreadsheet or a scanner, note that 111221, 111229, and 111231 are not part of this set.

The 26.07.1/2.9.1 release notes describe a maintenance release with security and high-priority fixes, including an updated PHP. The table below is illustrative, not exhaustive: it pulls out the advisory-related fixes named in the notes and the two advisories we reviewed directly.

ComponentIssue typeTracking
QinQ member tag removalAuthenticated command executionSA-26_23, CVE-2026-111214, #17170
Mobile IPsec login bannerCommand executionSA-26_26, CVE-2026-111223, #17177
Gateway Monitor IPCommand execution#17211
Dynamic DNSArbitrary file read#17215
IPv4 DHCP client hostnameCommand execution#17216
OpenVPN authentication and DNS ResolverCommand execution#17229, #17231
PPPoE reset and serverCommand execution#17232, #17233
firewall_rules.phpCross-site scripting#17194

Two examples worth understanding

SA-26_23 (CVE-2026-111214, credited to Abraxas Labs) describes authenticated command execution in interfaces_qinq_edit.php through the Parent Interface parameter. It affects Plus 26.07 and earlier and CE 2.9.0 and earlier. The advisory is specific about the trigger: creating a QinQ instance is not dangerous, but editing an existing one and removing member tags is. Netgate's workaround is to limit access to the affected pages to trusted administrators only. Most small sites never touch QinQ, but the pattern matters because it repeats across the release: a GUI field passes input into a shell command.

The mobile IPsec login banner flaw, CVE-2026-111223, is the one to look at if you run remote access VPN for clinicians or billing staff. VulnCheck's entry maps it to Netgate advisory SA-26_26, rates it CVSS 8.6 (v4), and describes it as running commands as root through the login_banner field. Exploiting it requires IPsec Mobile privileges, not necessarily full administrator rights. VulnCheck lists affected versions as CE 2.7.0 up to (but not including) 2.9.1 and Plus before 26.07.1, so firewalls that have been left on an older CE release are in scope. The entry also links to public technical write-ups from Abraxas Labs, the researchers credited with the finding.

The Fixes That Are Not on the Advisory List

Some of the most consequential changes in this release are not GUI bugs at all. According to Netgate's blog, the 26.07.1/2.9.1 release was driven by a FreeBSD IPsec nonce-handling vulnerability, FreeBSD-SA-26:82.ipsec, which Netgate found, reported to FreeBSD, and held under embargo until coordinated disclosure. The release notes list it as IPsec AES-GCM and ChaCha20-Poly1305 nonce reuse on multi-core systems (#17263). That is a weakness in the tunnel encryption itself, and it matters for any site-to-site IPsec tunnel carrying clinical or billing traffic between locations, regardless of who can log in to the GUI.

The same notes also fix kernel memory corruption in netlink message handling (#17262), a kernel panic when disabling pflow (#17186), and dropped IPv4 fragments on iflib NICs (#17196). The November 19 follow-up (26.07.2/2.9.2) adds PHP 8.5.13, nginx 1.30.7, and eighteen FreeBSD security advisories and errata notices, and it disables the acpi_spmc driver, which could cause a kernel panic on some hardware.

How Exposed Are You?

CERT-FR's advisory does not say whether authentication is required for each issue. The pages we reviewed do: SA-26_23 and the release notes describe the command execution items as authenticated, and the banner flaw requires IPsec Mobile privileges. We have not reviewed all nineteen advisories individually, so do not assume every one of them requires a login.

Authentication requirements reduce risk, but they do not remove it. Ask yourself three questions:

  • Can the web GUI be reached from anything other than a dedicated management network or management VPN?
  • Does anyone besides the IT staff, such as a vendor, a former contractor, or a shared account, have GUI or IPsec Mobile privileges?
  • Are the admin passwords on this firewall unique and stored somewhere other than a sticky note in the server closet?

If any answer makes you uncomfortable, fix that before or alongside the upgrade. In the Netgate forum thread on the release, one user argued the updated PHP matters less when the GUI is not publicly reachable, and another replied by pointing to the captive portal. That is a fair reminder: if you run a guest or patient Wi-Fi captive portal on pfSense, the firewall is serving web pages to untrusted users even when the admin GUI is locked down. Moving management access onto its own segment is also one of the simplest first steps in a zero trust approach.

On exploitation, we found no primary statement from Netgate or CERT-FR reporting active exploitation as of November 23, 2026. Public technical write-ups exist for at least the banner flaw, though, and edge devices tend to attract attention quickly once details are out. Treat the absence of exploitation reports as a window, not a reason to wait.

Upgrade Guidance for Small Teams

A Netgate staff member confirmed in the forum that upgrading directly to 26.07.2 or 2.9.2 includes all fixes from the November 17 release, so there is no need to step through 2.9.1 first. The 26.07.2/2.9.2 release notes point readers back to the 26.07.1/2.9.1 notes for changes that may matter on devices not yet updated, so read both before you start.

For a solo administrator at a small hospital or clinic, a practical sequence looks like this:

  1. Take a configuration backup and store it off the firewall.
  2. Check for the update manually rather than waiting for a notification. In the forum thread, one user said they did not know 2.9.1 existed and asked Netgate to feed the update check into the notification system.
  3. Confirm the device has free disk space. One forum user's Netgate 4200 failed to update with an out of space error until old ZFS boot environments were removed.
  4. Schedule a maintenance window with someone available on site or with console access, especially for remote clinics where the firewall is the only path back in.
  5. After the upgrade, confirm IPsec and OpenVPN tunnels reconnect and that clinical applications reach their servers before you close the window.

Forum reports so far describe successful upgrades on several Netgate models. Those are user comments, not vendor guidance, but they are a reasonable sign that the release is not causing widespread breakage.

If you cannot upgrade this week

The release notes say the PHP and shell code security fixes are available through the Recommended System Patches function for Plus 26.07 and 26.03.1 and for CE 2.9.0 and 2.8.1. SA-26_23 adds that the patches can be applied manually on earlier versions. The notes also say the updated PHP is available to prior releases without upgrading. Keep in mind that System Patches cover the PHP and shell code fixes, not the FreeBSD kernel and IPsec fixes, which come with the full release. Until you upgrade, restrict GUI access to trusted administrators on a management network.

OpenVPN and IKEv1

If you terminate OpenVPN on pfSense, review those configurations after the upgrade, since SA-26_35 and SA-26_36 both apply to the OpenVPN module and the release notes list two OpenVPN authentication and DNS Resolver command execution fixes.

The release notes also carry a longer-term warning: IKEv1 is deprecated and will be removed within the next year. Netgate says to migrate IKEv1 tunnels to IKEv2 as soon as possible, including mobile tunnels using Xauth and L2TP/IPsec. Older site-to-site tunnels to partner hospitals, reference labs, or imaging vendors are the usual places IKEv1 hides. Inventory them now, because the other end of each tunnel belongs to someone else and coordinating a change can take weeks.

The Compliance Angle

The HIPAA Security Rule does not mention firewalls by name, but a perimeter firewall supports several technical safeguards in 45 CFR 164.312. The access control standard at 164.312(a)(1) requires technical policies and procedures that allow access to systems maintaining ePHI only to persons or software programs that have been granted access rights. A firewall with a command execution flaw undercuts that control. The audit controls standard at 164.312(b) requires mechanisms that record and examine activity in systems containing or using ePHI, which is a good reason to review GUI login and configuration change logs after this cycle. The transmission security standard at 164.312(e)(1) requires technical measures to guard against unauthorized access to ePHI transmitted over an electronic communications network, which is exactly what your IPsec and OpenVPN tunnels do. Its encryption specification at 164.312(e)(2)(ii) is Addressable, and Addressable does not mean optional: you either implement it or document why an equivalent alternative is in place.

Patching the firewall promptly and documenting when and how you did it is the simplest way to show those safeguards are working. For more on how patching fits into HIPAA expectations, see our guide to HIPAA software patching requirements.

A Busy Month for Edge Devices

pfSense is not alone this month. OPNsense, its closest open source relative, recently fixed four authenticated vulnerabilities, including a root-level PPP flaw, and SonicWall patched an exploited SSL-VPN MFA bypass the same day Netgate published these advisories. Whatever sits at your edge, the pattern holds: keep management interfaces off untrusted networks, limit who holds administrative and VPN privileges, and treat firewall updates as routine maintenance rather than an emergency.

This article is for informational purposes only and does not constitute legal or compliance advice. Covered entities and business associates should consult qualified legal counsel or compliance professionals before making decisions pertaining to HIPAA or IT infrastructure.

Sources

About the Author

Health Tech Authority Editorial Team

Health Tech Authority is a publication covering the technology side of health care organizations. We exist for the people in the mix - the systems administrators keeping servers online at 2 AM, the network engineers segmenting clinical VLANs on a shoestring budget, the security officers trying to hold the HIPAA line with half the resources a comparably sized non-health care organization would have, and the IT managers and administrators making technology decisions that directly affect patient care.

Content published under this account represents collaborative editorial work produced by the Health Tech Authority team. That includes original reporting, technical analysis, regulatory coverage, and practitioner-focused guidance across our core coverage areas: infrastructure and systems administration, networking, security and compliance, cloud and Microsoft 365 administration, clinical systems and health data, and the broader technology landscape serving health care organizations.

We cover what health care IT professionals actually need to know, written in a way that respects both their time and their intelligence. No fluff, no vendor press release rewrites, no thought leadership buzzword soup - just straightforward coverage of the systems, tools, and decisions that keep health care organizations running.

If you have a topic suggestion, a correction, or want to contribute, reach out through the Contact page.